Results 1 - 20 de 52.886
Filter
1.
Ren Fail ; 46(1): 2349123, 2024 Dec.
Article in English | MEDLINE | ID: mdl-38727002

ABSTRACT

BACKGROUND: Laparoscopic techniques are being widely applied for peritoneal dialysis (PD) catheter (PDC) placement. The suture passer is a novel fixation tool that aims to reduce catheter migration. We compared the clinical value of the suture passer combined with two-hole laparoscopic PDC placement to open surgical placement by evaluating preoperative and postoperative conditions, as well as the onset of complications in both groups. METHODS: A retrospective study was conducted including 169 patients who underwent PDC placement surgery from January 2021 to May 2023. Based on the method employed, patients were divided into two groups: the suture passer combined with a two-hole laparoscopy group (SLG) and the open surgical group (SG). Comprehensive patient information, including general data, preoperative and postoperative indicators, peritoneal function after surgery, and the incidence rate of complications, were collected and analyzed. RESULTS: The SLG showed a statistically significant decrease in operative time, intraoperative blood loss, and 6-month postoperative drift rate compared to the SG (p < 0.05). No statistically significant differences were observed between the two groups in terms of sex, age, primary disease, hospitalization time, hospitalization costs, preoperative and postoperative examination indicators, peritonitis, and omental wrapping. CONCLUSIONS: Suture passer combined with two-hole laparoscopic PDC placement, characterized by simplicity and facilitating secure catheter fixation, was deemed safe and effective for patients undergoing PD. It reduces the catheter migration rate and improved surgical comfort. Overall, this technique demonstrates favorable outcomes in clinical practice.


Subject(s)
Laparoscopy , Peritoneal Dialysis , Humans , Male , Female , Laparoscopy/methods , Retrospective Studies , Middle Aged , Peritoneal Dialysis/methods , Peritoneal Dialysis/instrumentation , Aged , Catheterization/methods , Adult , Catheters, Indwelling , Operative Time , Postoperative Complications/epidemiology , Postoperative Complications/etiology , Postoperative Complications/prevention & control , Kidney Failure, Chronic/therapy , Suture Techniques
2.
Pediatr Surg Int ; 40(1): 128, 2024 May 09.
Article in English | MEDLINE | ID: mdl-38722444

ABSTRACT

INTRODUCTION: Continuous ambulatory peritoneal dialysis is an important modality of renal replacement therapy in children. Catheter dysfunction (commonly obstruction) is a major cause of morbidity and is a significant concern that hampers renal replacement therapy. As omentum is a significant cause of obstruction, some recommend routine omentectomy during insertion of the peritoneal dialysis catheter. Omentopexy rather than omentectomy has been described in adults to spare the omentum as it may be needed as a spare part in many conditions. Laparoscopic approach is commonly preferred as it provides global evaluation of the peritoneal space, proper location of the catheteral end in the pelvis and lesser morbidity due to inherent minimally invasive nature. AIM: The aim of this study is to present the technique of laparoscopic peritoneal dialysis catheter placement in children with concurrent omentopexy. METHODS: We retrospectively evaluated our patients who underwent laparoscopic placement of peritoneal dialysis catheter with concomitant omentopexy or omentectomy. RESULTS: A total of 30 patients were enrolled who received either omentectomy (n = 18) or omentopexy (n = 12). Four catheters were lost in the omentopexy group (33%) and 3 in the omentectomy group (17%), but none were related to omental obstruction. Three out of 4 patients in the omentopexy group and 2 out of 3 patients in the omentectomy group had a previous abdominal operation as a potential cause of catheter loss. Previous history of abdominal surgery was present in 6 patients (50%) in the omentopexy group and 3 patients (17%) in the omentectomy group. CONCLUSIONS: As omentum was associated with catheter failure, omentectomy is commonly recommended. Alternatively, omentopexy can be preferred in children to spare an organ that may potentially be necessary for many surgical reconstructive procedures in the future. Laparoscopic peritoneal dialysis catheter placement with concomitant omentopexy appears as a feasable and reproducible technique. Although the catheter loss seems to be higher in the omentopexy group, none was related with the omentopexy procedure and may be related to the higher rate of history of previous abdominal operations in this group.


Subject(s)
Laparoscopy , Omentum , Humans , Omentum/surgery , Laparoscopy/methods , Retrospective Studies , Male , Female , Child , Child, Preschool , Catheterization/methods , Adolescent , Catheters, Indwelling , Peritoneal Dialysis/methods , Peritoneal Dialysis, Continuous Ambulatory/methods , Infant , Treatment Outcome
3.
Anesthesiol Clin ; 42(2): 317-328, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38705679

ABSTRACT

Continuous peripheral nerve block catheters are simple in concept: percutaneously inserting a catheter adjacent to a peripheral nerve. This procedure is followed by local anesthetic infusion via the catheter that can be titrated to effect for extended anesthesia or analgesia in the perioperative period. The reported benefits of peripheral nerve catheters used in the surgical population include improved pain scores, decreased narcotic use, decreased nausea/vomiting, decreased pruritus, decreased sedation, improved sleep, and improved patient satisfaction.


Subject(s)
Catheters , Nerve Block , Humans , Anesthetics, Local/administration & dosage , Catheterization/methods , Nerve Block/methods , Peripheral Nerves
4.
Article in English | MEDLINE | ID: mdl-38696241

ABSTRACT

In this video tutorial, we present the cannulation technique for venopulmonary extracorporeal membrane oxygenation using the ProtekDuo dual-lumen cannula in a patient with acute respiratory distress syndrome.


Subject(s)
Cannula , Extracorporeal Membrane Oxygenation , Respiratory Distress Syndrome , Humans , Extracorporeal Membrane Oxygenation/methods , Respiratory Distress Syndrome/therapy , Catheterization/methods , Male
5.
Zhong Nan Da Xue Xue Bao Yi Xue Ban ; 49(1): 1-10, 2024 Jan 28.
Article in English, Chinese | MEDLINE | ID: mdl-38615160

ABSTRACT

OBJECTIVES: The distribution characteristics of intrathecal drugs and the limitation of current catheterization techniques make traditional intrathecal analgesic treatment nearly useless for refractory craniofacial pain, such as trigemina neuralgia. This technical guideline aims to promote the widespread and standardize the application of intra-prepontine cisternal drug delivery via spinal puncture and catheterization. METHODS: A modified Delphi approach was used to work for this guideline. On the issues related to the intra-prepontine cisternal targeted drug delivery technique, the working group consulted 10 experts from the field with 3 rounds of email feedback and 3 rounds of conference discussion. RESULTS: For the efficacy and safety of the intra-prepontine cisternal targeted drug delivery technique, a consensus was formed on 7 topics (with an agreement rate of more than 80%), including the principles of the technique, indications and contraindications, patient preparation, surgical specifications for intra-prepontine cisternal catheter placement, analgesic dosage coordination, analgesic management, and prevention and treatment of complications. CONCLUSIONS: Utilizing the intra-prepontine cisternal drug infusion system to manage refractory craniofacial pain could provide advantages in terms of minimally invasive, secure, and effective treatment. This application can not only alleviate the suffering of individuals experiencing the prolonged pain but also support the maintenance of quality of life and dignity in their final moments, justifiing its widespread dissemination and standardized adoption in domestic and international professional fields.


Subject(s)
Quality of Life , Spinal Puncture , Humans , Facial Pain , Catheterization , Analgesics
6.
Radiologia (Engl Ed) ; 66 Suppl 1: S24-S31, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38642957

ABSTRACT

INTRODUCTION: There are no defined criteria for deciding to remove a non-functioning indwelling pleural catheter (IPC) when lung re-expansion on chest X-ray is incomplete. Chest computed tomography (chest CT) is usually used. The objective of this work is to validate the usefulness of chest ultrasound performed by a pulmonologist and by a radiologist compared to chest CT. PATIENTS AND METHODS: Prospective, descriptive, multidisciplinary and multicenter study including patients with malignant pleural effusion and non-functioning IPC without lung reexpansion. Decisions made on the basis of chest ultrasound performed by a pulmonologist, and performed by a radiologist, were compared with chest CT as the gold standard. RESULTS: 18 patients were analyzed, all of them underwent ultrasound by a pulmonologist and chest CT and in 11 of them also ultrasound by a radiologist. The ultrasound performed by the pulmonologist presents a sensitivity of 60%, specificity of 100%, PPV 100% and NPV 66% in the decision of the correct removal of the IPC. The concordance of both ultrasounds (pulmonologist and radiologist) was 100%, with a kappa index of 1. The 4 discordant cases were those in which the IPC was not located on the ultrasound. CONCLUSIONS: Thoracic ultrasound performed by an expert pulmonologist is a valid and simple tool to determine spontaneous pleurodesis and remove a non-functioning IPC, which would make it possible to avoid chest CT in those cases in which lung reexpansion is observed with ultrasonography.


Subject(s)
Pleural Effusion, Malignant , Humans , Pleural Effusion, Malignant/diagnostic imaging , Pleural Effusion, Malignant/therapy , Pleural Effusion, Malignant/pathology , Prospective Studies , Catheterization , Catheters, Indwelling , Ultrasonography
7.
Perfusion ; 39(1_suppl): 23S-38S, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38651584

ABSTRACT

Limb ischaemia is a clinically relevant complication of venoarterial extracorporeal membrane oxygenation (VA ECMO) with femoral artery cannulation. No selective distal perfusion or other advanced techniques were used in the past to maintain adequate distal limb perfusion. A more recent trend is the shift from the reactive or emergency management to the pro-active or prophylactic placement of a distal perfusion cannula to avoid or reduce limb ischaemia-related complications. Multiple alternative cannulation techniques to the distal perfusion cannula have been developed to maintain distal limb perfusion, including end-to-side grafting, external or endovascular femoro-femoral bypass, retrograde limb perfusion (e.g., via the posterior tibial, dorsalis pedis or anterior tibial artery), and, more recently, use of a bidirectional cannula. Venous congestion has also been recognized as a potential contributing factor to limb ischaemia development and specific techniques have been described with facilitated venous drainage or bilateral cannulation being the most recent, to reduce or avoid venous stasis as a contributor to impaired limb perfusion. Advances in monitoring techniques, such as near-infrared spectroscopy and duplex ultrasound analysis, have been applied to improve decision-making regarding both the monitoring and management of limb ischaemia. This narrative review describes the evolution of techniques used for distal limb perfusion during peripheral VA ECMO.


Subject(s)
Extracorporeal Membrane Oxygenation , Femoral Artery , Humans , Extracorporeal Membrane Oxygenation/methods , Perfusion/methods , Catheterization/methods , Ischemia/prevention & control , Ischemia/etiology , Adult , Catheterization, Peripheral/methods , Catheterization, Peripheral/adverse effects , Extremities/blood supply
8.
Innovations (Phila) ; 19(2): 192-195, 2024.
Article in English | MEDLINE | ID: mdl-38606852

ABSTRACT

OBJECTIVE: Femoral artery cannulation is the most commonly used approach for cardiopulmonary bypass (CPB) in robotic cardiac procedures. However, without adding a distal perfusion cannula, leg ischemia can occur in up to 11.5% of patients. There is a well-described 2 to 4 mm size arterial branch that originates from the medial side of the external iliac artery or inferior epigastric artery, immediately above the inguinal ligament, and connects to the obturator artery. Therefore, it was historically named the corona mortis, which means "crown of death" in Latin. When peripheral cannulation is performed above this branch in the external iliac artery, we consider it a corona "vitae" because of its role as a limb-saving collateral. We report herein our standard technique of peripheral cannulation without the need of a distal perfusion cannula and preventing limb ischemia. METHODS: We included all patients who underwent robotic cardiac surgery with peripheral cannulation over a 16-month period at our institution. We cannulated just above the level of the inguinal ligament through a 2 to 3 cm transverse skin incision. The incidence of limb ischemia and vascular complications was recorded and analyzed. RESULTS: During the study period, 133 patients underwent robotic cardiac procedures with peripheral "external iliac" CPB. The size of the cannula was 21F or larger in 73% and 23F in 54% of the patients. No leg ischemia or femoral artery complications requiring additional intervention occurred. CONCLUSIONS: External iliac cannulation can be successfully performed in robot-assisted cardiac surgery using relatively large cannulas without the need of a distal limb perfusion catheter, with good results. In our view, given the importance of the corona mortis ("crown of death" in Latin) in perfusing the limb during CPB, we propose a new name for this artery in robotic cardiac surgery, namely, the corona vitae ("crown of life" in Latin).


Subject(s)
Iliac Artery , Robotic Surgical Procedures , Humans , Iliac Artery/surgery , Robotic Surgical Procedures/methods , Male , Female , Aged , Cardiac Surgical Procedures/methods , Cardiopulmonary Bypass/methods , Middle Aged , Ischemia/prevention & control , Catheterization, Peripheral/methods , Femoral Artery/surgery , Catheterization/methods
9.
Sci Rep ; 14(1): 8784, 2024 04 16.
Article in English | MEDLINE | ID: mdl-38627500

ABSTRACT

Eustachian tube balloon dilatation (ETBD) has shown promising results in the treatment of ET dysfunction (ETD); however, recurrent symptoms after ETBD frequently occur in patients with refractory ETD. The excessive pressure of balloon catheter during ETBD may induce the tissue hyperplasia and fibrotic changes around the injured mucosa. Sirolimus (SRL), an antiproliferative agent, inhibits tissue proliferation. An SRL-coated balloon catheter was fabricated using an ultrasonic spray coating technique with a coating solution composed of SRL, purified shellac, and vitamin E. This study aimed to investigate effectiveness of ETBD with a SRL-coated balloon catheter to prevent tissue proliferation in the rat ET after ETBD. In 21 Sprague-Dawley rats, the left ET was randomly divided into the control (drug-free ETBD; n = 9) and the SRL (n = 9) groups. All rats were sacrificed for histological examination immediately after and at 1 and 4 weeks after ETBD. Three rats were used to represent the normal ET. The SRL-coated ETBD significantly suppressed tissue proliferation caused by mechanical injuries compared with the control group. ETBD with SRL-coated balloon catheter was effective and safe to maintain ET luminal patency without tissue proliferation at the site of mechanical injuries for 4 weeks in a rat ET model.


Subject(s)
Ear Diseases , Eustachian Tube , Humans , Rats , Animals , Dilatation/methods , Rats, Sprague-Dawley , Catheterization/methods , Ear Diseases/therapy , Ear Diseases/diagnosis , Treatment Outcome
10.
J Am Heart Assoc ; 13(8): e033290, 2024 Apr 16.
Article in English | MEDLINE | ID: mdl-38591330

ABSTRACT

BACKGROUND: Noninvasive pulse waveform analysis is valuable for central cardiovascular assessment, yet controversies persist over its validity in peripheral measurements. Our objective was to compare waveform features from a cuff system with suprasystolic blood pressure hold with an invasive aortic measurement. METHODS AND RESULTS: This study analyzed data from 88 subjects undergoing concurrent aortic catheterization and brachial pulse waveform acquisition using a suprasystolic blood pressure cuff system. Oscillometric blood pressure (BP) was compared with invasive aortic systolic BP and diastolic BP. Association between cuff and catheter waveform features was performed on a set of 15 parameters inclusive of magnitudes, time intervals, pressure-time integrals, and slopes of the pulsations. The evaluation covered both static (subject-averaged values) and dynamic (breathing-induced fluctuations) behaviors. Peripheral BP values from the cuff device were higher than catheter values (systolic BP-residual, 6.5 mm Hg; diastolic BP-residual, 12.4 mm Hg). Physiological correction for pressure amplification in the arterial system improved systolic BP prediction (r2=0.83). Dynamic calibration generated noninvasive BP fluctuations that reflect those invasively measured (systolic BP Pearson R=0.73, P<0.001; diastolic BP Pearson R=0.53, P<0.001). Static and dynamic analyses revealed a set of parameters with strong associations between catheter and cuff (Pearson R>0.5, P<0.001), encompassing magnitudes, timings, and pressure-time integrals but not slope-based parameters. CONCLUSIONS: This study demonstrated that the device and methods for peripheral waveform measurements presented here can be used for noninvasive estimation of central BP and a subset of aortic waveform features. These results serve as a benchmark for central cardiovascular assessment using suprasystolic BP cuff-based devices and contribute to preserving system dynamics in noninvasive measurements.


Subject(s)
Arterial Pressure , Blood Pressure Determination , Humans , Blood Pressure/physiology , Arterial Pressure/physiology , Blood Pressure Determination/methods , Aorta/physiology , Catheterization
11.
JAMA ; 331(13): 1099-1108, 2024 04 02.
Article in English | MEDLINE | ID: mdl-38563835

ABSTRACT

Importance: Left atrial appendage elimination may improve catheter ablation outcomes for atrial fibrillation. Objective: To assess the safety and effectiveness of percutaneous left atrial appendage ligation adjunctive to catheter pulmonary vein isolation for nonparoxysmal atrial fibrillation. Design, Setting, and Participants: This multicenter, prospective, open-label, randomized clinical trial evaluated the safety and effectiveness of percutaneous left atrial appendage ligation adjunctive to planned pulmonary vein isolation for nonparoxysmal atrial fibrillation present for less than 3 years. Eligible patients were randomized in a 2:1 ratio to undergo left atrial appendage ligation and pulmonary vein isolation or pulmonary vein isolation alone. Use of a 2:1 randomization ratio was intended to provide more device experience and safety data. Patients were enrolled from October 2015 to December 2019 at 53 US sites, with the final follow-up visit on April 21, 2021. Interventions: Left atrial appendage ligation plus pulmonary vein isolation compared with pulmonary vein isolation alone. Main Outcomes and Measures: A bayesian adaptive analysis was used for primary end points. Primary effectiveness was freedom from documented atrial arrythmias of greater than 30 seconds duration 12 months after undergoing pulmonary vein isolation. Rhythm was assessed by Holter monitoring at 6 and 12 months after pulmonary vein isolation, symptomatic event monitoring, or any electrocardiographic tracing obtained through 12 months after pulmonary vein isolation. Primary safety was a composite of predefined serious adverse events compared with a prespecified 10% performance goal 30 days after the procedure. Left atrial appendage closure was evaluated through 12 months after pulmonary vein isolation. Results: Overall, 404 patients were randomized to undergo left atrial appendage ligation plus pulmonary vein isolation and 206 were randomized to undergo pulmonary vein isolation alone. Primary effectiveness was 64.3% with left atrial appendage ligation and pulmonary vein isolation and 59.9% with pulmonary vein isolation only (difference, 4.3% [bayesian 95% credible interval, -4.2% to 13.2%]; posterior superiority probability, 0.835), which did not meet the statistical criterion to establish superiority (0.977). Primary safety was met, with a 30-day serious adverse event rate of 3.4% (bayesian 95% credible interval, 2.0% to 5.0%; posterior probability, 1.0) which was less than the prespecified threshold of 10%. At 12 months after pulmonary vein isolation, complete left atrial appendage closure (0 mm residual communication) was observed in 84% of patients and less than or equal to 5 mm residual communication was observed in 99% of patients. Conclusions and Relevance: Percutaneous left atrial appendage ligation adjunctive to pulmonary vein isolation did not meet prespecified efficacy criteria for freedom from atrial arrhythmias at 12 months compared with pulmonary vein isolation alone for patients with nonparoxysmal atrial fibrillation, but met prespecified safety criteria and demonstrated high rates of closure at 12 months. Trial Registration: ClinicalTrials.gov Identifier: NCT02513797.


Subject(s)
Atrial Appendage , Atrial Fibrillation , Organothiophosphorus Compounds , Pulmonary Veins , Humans , Atrial Appendage/surgery , Atrial Fibrillation/surgery , Bayes Theorem , Prospective Studies , Pulmonary Veins/surgery , Catheter Ablation , Catheterization
12.
Medicina (Kaunas) ; 60(4)2024 Apr 22.
Article in English | MEDLINE | ID: mdl-38674325

ABSTRACT

Background and Objectives: Thoracic epidural catheterization (TEC) can be both uncomfortable and fearful for patients when performed awake with the thought that the procedure may be painful. The aim of this study was to assess the effect of low-dose intravenous ketamine administration on pain and anxiety during the TEC procedure. Materials and Methods: Sixty patients were randomly divided into two groups to receive intravenous (IV) placebo (Group P) and IV low-dose (0.15 mg/kg) ketamine (LDK) (Group K) 3 min before the procedure in a double-blind manner. A visual analog scale (VAS) was used to measure anxiety (VAS-A) and pain (VAS-P) scores. Vital parameters were monitored before premedication (T1), 20 min after premedication (T2), during skin anesthesia (T3), during TEC (T4), and 5 min after TEC (T5). VAS-A values were recorded at T1, T3, T4, and T5 periods, and VAS-P levels were noted at T3, T4, and T5 periods. Results: During TEC (T4), both VAS-P and VAS-A were significantly lower in Group K (p < 0.001). The mean VAS-A value was 10.6 mm lower, and the mean VAS-P value was 9 mm lower in Group K than in Group P at the T4 time point. Additionally, the mean VAS-P value was 7.7 mm lower in Group K compared to Group P at the T3 time point (p < 0.001). Both groups showed a statistically significant difference in VAS-A measurements when compared at their respective time points (p < 0.001). However, only Group P demonstrated a statistically significant difference in VAS-P measurements (p < 0.001). VAS-P values remained stable in Group K. The number of patients who did not recall the procedure was significantly higher in Group K (p < 0.001). Furthermore, the number of patients who would consent to the same procedure in the future was significantly higher in Group K (p = 0.007). Conclusions: A preprocedural LDK (0.15 mg/kg) can effectively prevent anxiety and pain experienced by patients during the TEC procedure. Administration of LDK may provide a more comfortable procedure process without causing ketamine-induced side effects (hemodynamic, respiratory, and psychological).


Subject(s)
Anxiety , Ketamine , Pain Measurement , Humans , Ketamine/administration & dosage , Ketamine/therapeutic use , Male , Female , Double-Blind Method , Anxiety/prevention & control , Anxiety/drug therapy , Adult , Middle Aged , Pain Measurement/methods , Analgesics/therapeutic use , Analgesics/administration & dosage , Catheterization/methods , Catheterization/adverse effects , Pain/drug therapy , Pain/prevention & control , Pain/psychology , Anesthesia, Epidural/methods
15.
Medicine (Baltimore) ; 103(14): e37638, 2024 Apr 05.
Article in English | MEDLINE | ID: mdl-38579027

ABSTRACT

RATIONALE: Guide wire aspiration during central venous catheter (CVC) insertion in a patient on extracorporeal membrane oxygenation (ECMO) is a very rare but dangerous complication. A guide wire aspirated inside the ECMO can cause thrombosis, the ECMO to break down or shut off, and unnecessary ECMO replacement. PATIENT CONCERNS: A 58-year-old man was scheduled for venovenous ECMO for acute respiratory distress syndrome. After his vital signs stabilized, we inserted a CVC. During CVC insertion, the guide wire was aspirated into the ECMO venous line. INTERVENTION: After confirming the guide wire inside the ECMO venous line, we replaced the entire ECMO circuit. OUTCOMES: ECMO was maintained for 57 days, and weaning was successful but the patient died 5 days afterward. LESSONS: Care must be taken when inserting a CVC using a guide wire in ECMO patients: the guide wire should not be inserted deeply, it should be secured during insertion, the ECMO venous cannula tip requires proper positioning, and ECMO flow should be temporarily reduced.


Subject(s)
Central Venous Catheters , Extracorporeal Membrane Oxygenation , Respiratory Distress Syndrome , Male , Humans , Middle Aged , Catheterization , Respiratory Distress Syndrome/etiology , Respiratory Distress Syndrome/therapy , Respiratory Aspiration
16.
J Cardiothorac Surg ; 19(1): 122, 2024 Mar 13.
Article in English | MEDLINE | ID: mdl-38481279

ABSTRACT

BACKGROUND: Ultrasound-guided percutaneous axillary vein cannulation can reduce cannulation failure and mechanical complications, is as safe and effective as internal jugular vein cannulation, and is superior to subclavian vein cannulation using landmark technique. As far, reports of venovenous extracorporeal membrane oxygenation (VV-ECMO) with percutaneous axillary vein cannulation are rare. CASE PRESENTATION: A 64-year-old man presenting with dyspnea and chest tightness after aspirating sewage was admitted to the emergency department. Computed tomography (CT) showed diffuse exudation of both lungs and arterial blood gas analysis showed an oxygenation index of 86. He was diagnosed with aspiration pneumonia-induced acute respiratory distress syndrome (ARDS) and intubated for deteriorated oxygenation. Despite the combination therapy of protective mechanical ventilation and prone position, the patient's oxygenation deteriorated further, accompanied with multiple organ dysfunction syndrome, which indicated the requirement of support with VV-ECMO. However, vascular ultrasound detected multiple thrombus within bilateral internal jugular veins. As an alternative, right axillary vein was chosen as the access site of return cannula. Subsequently, femoral-axillary VV-ECMO was successfully implemented under the ultrasound guidance, and the patient's oxygenation was significantly improved. Unfortunately, the patient died of hyperkalemia-induced ventricular fibrillation after 36 h of VV-ECMO running. Despite the poor prognosis, the blood flow during ECMO run was stable, and we observed no bleeding complication, vascular injury, or venous return disorder. CONCLUSIONS: Axillary vein is a feasible alternative access site of return cannula for VV-ECMO if internal jugular vein access were unavailable.


Subject(s)
Extracorporeal Membrane Oxygenation , Vascular Diseases , Male , Humans , Middle Aged , Extracorporeal Membrane Oxygenation/methods , Axillary Vein/diagnostic imaging , Catheterization , Cannula , Jugular Veins
17.
Comput Biol Med ; 172: 108263, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38489988

ABSTRACT

PROBLEM: Despite advances in Venoarterial Extracorporeal Membrane Oxygenation (VA-ECMO), a significant mortality rate persists due to complications. The non-physiological blood flow dynamics of VA-ECMO may lead to neurological complications and organ ischemia. Continuous retrograde high-flow oxygenated blood enters through a return cannula placed in the femoral artery which opposes the pulsatile deoxygenated blood ejected by the left ventricle (LV), which impacts upper body oxygenation and subsequent hyperoxemia. The complications underscore the critical need to comprehend the impact of VA-ECMO support level and return cannula size, as mortality remains a significant concern. AIM: The aim of this study is to predict and provide insights into the complications associated with VA-ECMO using computational fluid dynamics (CFD) simulations. These complications will be assessed by characterising blood flow and emboli transport patterns through a comprehensive analysis of the influence of VA-ECMO support levels and arterial return cannula sizes. METHODS: Patient-specific 3D aortic and major branch models, derived from a male patient's CT scan during VA-ECMO undergoing respiratory dysfunction, were analyzed using CFD. The investigation employed species transport and discrete particle tracking models to study ECMO blood (oxygenated) mixing with LV blood (deoxygenated) and to trace emboli transport patterns from potential sources (circuit, LV, and aorta wall). Two cannula sizes (15 Fr and 19 Fr) were tested alongside varying ECMO pump flow rates (50%, 70%, and 90% of the total cardiac output). RESULTS: Cannula size did not significantly affect oxygen transport. At 90% VA-ECMO support, all arteries distal to the aortic arch achieved 100% oxygen saturation. As support level decreased, oxygen transport to the upper body also decreased to a minimum saturation of 73%. Emboli transport varied substantially between emboli origin and VAECMO support level, with the highest risk of cerebral emboli coming from the LV with a 15 Fr cannula at 90% support. CONCLUSION: Arterial return cannula sizing minimally impacted blood oxygen distribution; however, it did influence the distribution of emboli released from the circuit and aortic wall. Notably, it was the support level alone that significantly affected the mixing zone of VA-ECMO and cardiac blood, subsequently influencing the risk of embolization of the cardiogenic source and oxygenation levels across various arterial branches.


Subject(s)
Extracorporeal Membrane Oxygenation , Male , Humans , Hydrodynamics , Hemodynamics/physiology , Catheterization , Oxygen
18.
Article in German | MEDLINE | ID: mdl-38513644

ABSTRACT

Arterial catheterization is considered to be standard procedure for patients undergoing general anesthesia. The most common puncture site is the radial artery (RA), which carries a risk of RA occlusion. Several pieces of literature still recommend the performance of the Allen test (AT) to assess the circulation of the palmar arch. However, the result of the AT differs largely depending on the examiner and the test is not able to predict ischemic events correctly. Thus it appears that the performance of an AT is not mandatory before arterial cannulation.


Subject(s)
Catheterization, Peripheral , Radial Artery , Humans , Catheterization , Hand/blood supply , Ischemia
19.
PLoS One ; 19(3): e0300713, 2024.
Article in English | MEDLINE | ID: mdl-38527053

ABSTRACT

INTRODUCTION: Although extracorporeal membrane oxygenation (ECMO) is a well-established treatment for supporting severe cardiopulmonary failure, the morbidity and mortality of patients requiring ECMO support remain high. Evaluating and correcting potential risk factors associated with any ECMO-related complications may improve care and decrease mortality. This study aimed to assess the predictors of ECMO-related vascular and cerebrovascular complications among adult patients and to test the hypothesis that ECMO-related complications are associated with higher in-hospital mortality rates. METHODS: This single-center, retrospective study included 856 ECMO runs administered via cannulation of the femoral vessels of 769 patients: venoarterial (VA) ECMO (n = 709, 82.8%) and venovenous (VV) ECMO (n = 147, 17.2%). The study outcomes included the occurrence of ECMO-related vascular and cerebrovascular complications and in-hospital death. The association of ECMO-related complications with the risk of in-hospital death was analyzed. RESULTS: The incidences of ECMO-related vascular and cerebrovascular complications were 20.2% and 13.6%, respectively. The overall in-hospital mortality rate was 48.7%: 52.8% among VA ECMO runs and 29.3% among VV ECMO runs. Multivariable analysis indicated that age (P < 0.01), cardiopulmonary cerebral resuscitation (P < 0.01), continuous renal replacement therapy (P < 0.01), and initial platelet count [<50×103/µL (P = 0.02) and 50-100(×103)/µL (P < 0.01)] were associated with an increased risk of in-hospital death. ECMO-related vascular and cerebrovascular complications were not independently associated with higher in-hospital mortality rates for VA or VV ECMO runs. CONCLUSION: ECMO-related vascular and cerebrovascular complications were not associated with an increased risk of in-hospital death among adult patients.


Subject(s)
Extracorporeal Membrane Oxygenation , Adult , Humans , Extracorporeal Membrane Oxygenation/adverse effects , Retrospective Studies , Hospital Mortality , Catheterization , Risk Factors
20.
Sci Rep ; 14(1): 7341, 2024 03 28.
Article in English | MEDLINE | ID: mdl-38538734

ABSTRACT

Endoscopic Retrograde Cholangiopancreatography (ERCP) is the primary therapeutic procedure for pancreaticobiliary disorders, and studies highlighted the impact of papilla anatomy on its efficacy and safety. Our objective was to quantify the influence of papilla morphology on ERCP outcomes. We systematically searched three medical databases in September 2022, focusing on studies detailing the cannulation process or the rate of adverse events in the context of papilla morphology. The Haraldsson classification served as the primary system for papilla morphology, and a pooled event rate with a 95% confidence interval was calculated as the effect size measure. Out of 17 eligible studies, 14 were included in the quantitative synthesis. In studies using the Haraldsson classification, the rate of difficult cannulation was the lowest in type I papilla (26%), while the highest one was observed in the case of type IV papilla (41%). For post-ERCP pancreatitis, the event rate was the highest in type II papilla (11%) and the lowest in type I and III papilla (6-6%). No significant difference was observed in the cannulation failure and post-ERCP bleeding event rates between the papilla types. In conclusion, certain papilla morphologies are associated with a higher rate of difficult cannulation and post-ERCP pancreatitis.


Subject(s)
Ampulla of Vater , Pancreatitis , Humans , Cholangiopancreatography, Endoscopic Retrograde/adverse effects , Cholangiopancreatography, Endoscopic Retrograde/methods , Catheterization/methods , Ampulla of Vater/surgery , Sphincterotomy, Endoscopic/adverse effects , Pancreatitis/etiology